Most popping and hollow-sounding tiles come down to too little adhesive under the tile. The notch on the trowel sets how thick the bed is, and the bed has to suit the tile: the larger and flatter the tile, the deeper the notch. This calculator uses the usual coverage for powder adhesive mixed with water, per square metre, for each notch size.
Which trowel for which tile
- 6 mm square notch: mosaics, metro and wall tiles up to about 300 mm. About 2.5 to 3 kg per m².
- 8 mm: floor and wall tiles from 300 to 450 mm. About 3.5 to 4 kg per m².
- 10 mm: 600 x 600 floor tiles and wood-look planks. About 4.5 to 5 kg per m².
- 12 mm: 600 x 1200, 800 x 800 and larger, uneven stone and outdoor floors. About 6 kg per m².
Add about 1.5 kg per m² for back-buttering, which means spreading a thin skim of adhesive on the back of each tile as well as on the floor. It is the usual way to reach full cover under large porcelain, outdoor tiles and anything in a shower, where a hollow spot lets water sit under the tile.
Choosing the adhesive
Bags are graded C1 (normal) or C2 (improved), with T for no slip on walls, E for extended open time and S1 for a flexible bed. Porcelain absorbs almost no water, so it needs a C2 adhesive or a C1 with a latex additive rather than plain tile cement. Use a flexible S1 adhesive outside, on balconies, over underfloor heating, on boards and on new screeds, because these all move with heat. Ask the supplier to match the bag to the tile and the base; see tile adhesive and grout for the grades and prices.
Check the coverage
Lift a freshly laid tile now and then. The back should be at least 80% covered indoors and 95% covered outside and in wet areas, with no bare corners. If it is not, use a bigger notch or back-butter. The calculator adds 10% for mixing losses and what dries in the bucket.